Responding to a LDH (Lactate Dehydrogenase) Deficiency on the CMS-2567

A strong plan of correction for a LDH finding names the fix, shows a look-back for affected patient results, changes the system that failed, assigns monitoring and gives a completion date, with the LDH records that prove it attached.

Last reviewed Nov 24, 2026 · By the Sound Lab Consultants regulatory team · Sources listed below

What a LDH plan of correction should cover

CMS returns plans that only promise to do better. Plans of correction generally need to explain:

  1. The fix: what was corrected for LDH and when.
  2. The look-back: how you found other LDH results or patients that may have been affected, and what you did about them.
  3. The system change: the procedure, training or software change that keeps it from happening again.
  4. The monitor: who checks it, how often, and where it is reported (for example to the laboratory director or QA meeting).
  5. The date: a realistic completion date for each item.

Evidence to attach for LDH

LDH PT and accuracy

LDH (Lactate Dehydrogenase) is a regulated analyte (routine chemistry, 42 CFR 493.931). CLIA PT acceptance limit: target value ±15%. If the finding involves PT, include the investigation of each unacceptable result and the remedial action taken; routine chemistry rules require that documentation be kept for two years (42 CFR 493.841).

Common root causes behind LDH findings

Related tests

Full guide: LDH (Lactate Dehydrogenase) testing in the clinical lab: CLIA, PT and QC requirements on soundlabconsult.com, part of the Laboratory Test Compliance Library.

For laboratory compliance and operations only, not medical advice or patient care guidance.

Received a 2567? Talk it through with a CLIA consultant

Sound Lab Consultants reviews CMS-2567 findings with laboratory directors, works through root causes and helps draft plans of correction and allegations of compliance.

Book a free consultation

Related guides on soundlabconsult.com:

Frequently asked questions

How do I write a plan of correction for a LDH deficiency?

State the correction, the look-back for affected LDH results, the system change, the monitoring and a completion date, and attach the supporting records.

What records support a LDH plan of correction?

Daily LDH QC records, Levey-Jennings charts, corrective action log, control lot ranges; Six-month LDH calibration verification and reportable range data with director review; LDH PT enrollment, attestation statements, graded reports, investigation of every miss.

Where is the plan of correction written?

On Form CMS-2567, the Statement of Deficiencies and Plan of Correction, or in the format your state agency or accrediting organization specifies.