Responding to a Compatibility Testing (Crossmatch) Deficiency on the CMS-2567
A strong plan of correction for a Crossmatch finding names the fix, shows a look-back for affected patient results, changes the system that failed, assigns monitoring and gives a completion date, with the Crossmatch records that prove it attached.
What a Crossmatch plan of correction should cover
CMS returns plans that only promise to do better. Plans of correction generally need to explain:
- The fix: what was corrected for Crossmatch and when.
- The look-back: how you found other Crossmatch results or patients that may have been affected, and what you did about them.
- The system change: the procedure, training or software change that keeps it from happening again.
- The monitor: who checks it, how often, and where it is reported (for example to the laboratory director or QA meeting).
- The date: a realistic completion date for each item.
Evidence to attach for Crossmatch
- Daily Crossmatch QC records, Levey-Jennings charts, corrective action log, control lot ranges
- Crossmatch PT enrollment, attestation statements, graded reports, investigation of every miss
- Crossmatch verification study: accuracy, precision, reportable range, reference interval check, director sign-off
- Critical value list, call log with read-back, report format showing Crossmatch reference intervals
- Training and competency records for everyone who runs Crossmatch
Crossmatch PT and accuracy
Compatibility Testing (Crossmatch) is a regulated analyte (immunohematology, 42 CFR 493.959). CLIA PT acceptance limit: 100% accuracy. If the finding involves PT, include the investigation of each unacceptable result and the remedial action taken; routine chemistry rules require that documentation be kept for two years (42 CFR 493.841).
Common root causes behind Crossmatch findings
- Positive patient identification at collection is the single most important control; use your two-identifier and labeling policy.
- ABO group must be determined with at least anti-A and anti-B reagents and confirmed by testing the serum with known A1 and B red cells (42 CFR 493.1271(a)(2)).
- Electronic crossmatch requires defined system validation and eligibility rules.
- Procedures that do not match what staff actually do.
- No second-level review of QC and calibration verification records.
Related tests
- ABO Group
- Unexpected Antibody Detection (Antibody Screen) (full guide)
- Antibody Identification (full guide)
Full guide: Compatibility Testing (Crossmatch) testing in the clinical lab: CLIA, PT and QC requirements on soundlabconsult.com, part of the Laboratory Test Compliance Library.
Received a 2567? Talk it through with a CLIA consultant
Sound Lab Consultants reviews CMS-2567 findings with laboratory directors, works through root causes and helps draft plans of correction and allegations of compliance.
Related guides on soundlabconsult.com:
Frequently asked questions
How do I write a plan of correction for a Crossmatch deficiency?
State the correction, the look-back for affected Crossmatch results, the system change, the monitoring and a completion date, and attach the supporting records.
What records support a Crossmatch plan of correction?
Daily Crossmatch QC records, Levey-Jennings charts, corrective action log, control lot ranges; Crossmatch PT enrollment, attestation statements, graded reports, investigation of every miss; Crossmatch verification study: accuracy, precision, reportable range, reference interval check, director sign-off.
Where is the plan of correction written?
On Form CMS-2567, the Statement of Deficiencies and Plan of Correction, or in the format your state agency or accrediting organization specifies.
Sources
- 42 CFR 493.959, Immunohematology
- Form CMS-2567, Statement of Deficiencies and Plan of Correction
- CMS State Operations Manual, Chapter 6 (Special Procedures for Laboratories)
- 42 CFR 493.1256, Control procedures
- 42 CFR 493.1255, Calibration and calibration verification
- 42 CFR 493 Subpart H, Participation in Proficiency Testing
- CMS State Operations Manual, Appendix C (Laboratories)